555 Timer Calculator
Astable Frequency · Duty Cycle · Monostable Pulse Width
Timing and component values
Calculate the timing of a circuit or find resistor values for your target waveform.
Set up your timing network
RA and RB set the high time. RB sets the low time.
Component tolerance
Enter symmetric limits from the part specs. The range covers R and C only.
Oscillator frequency
54.8% of each cycle is high.
- Period
- 720.9 µs
- High time
- 395.1 µs
- Low time
- 325.8 µs
- Output high duty
- 54.8%
Timing model and part selection
Astable: tH = ln(2)(RA + RB)C, tL = ln(2)RBC and f = 1/(tH + tL). Duty cycle is the high part of the period. This topology with positive resistors gives more than 50% high duty.
Monostable: tW = ln(3)RC, approximately 1.1RC, with a sufficiently short negative trigger pulse. The waveform assumes the capacitor starts discharged.
Use ideal timing for a first estimate. Round design results to available parts and recheck. Confirm resistor limits, capacitor leakage, supply decoupling, trigger behavior and actual timing for the chosen IC. Texas Instruments 555 datasheet, sections 6.3.1 and 6.3.2.
How to use this calculator
Design a repeating clock or a single timed pulse with a 555 timer. Choose astable mode for a repeating square wave or monostable mode for a one-shot. Start from the parts you have, or work backward from the timing you want.
Astable mode for a repeating square wave
In the standard two resistor circuit, the capacitor charges through RA and RB and discharges through RB. The 555’s internal comparators switch at approximately one third and two thirds of the supply voltage.
tlow = ln(2) × RB × C
Add the two times to get the period. Frequency is one divided by the period, and duty cycle is the fraction spent high. With RA = 10 kΩ, RB = 47 kΩ, and C = 10 nF, the audio oscillator example gives about 1.39 kHz with a 54.8% high duty cycle.
Monostable mode for a single timed pulse
A short trigger drives the output high and lets the capacitor charge through one resistor. When the capacitor reaches the upper threshold, the output returns low. The ideal pulse lasts ln(3) × R × C, often rounded to 1.1RC.
A 91 kΩ resistor and a 1 µF capacitor give about 100 milliseconds. To choose components for a target pulse, start with a capacitor that suits the time range and solve for its resistor. Keep the trigger short enough for the one-shot circuit described in the device datasheet.
From calculated timing to the bench
Start with the timing spread from component tolerance. Allow for capacitor leakage and variation, the timer’s threshold accuracy, temperature, and supply conditions as well. Check the datasheet for the exact 555 variant. A bipolar NE555 and a CMOS replacement can have different operating limits.
Frequently asked questions
What is the difference between astable and monostable modes?
Astable mode repeats high and low intervals without a separate trigger for each cycle. Monostable mode produces one timed output pulse in response to a trigger.
Can the standard astable 555 circuit reach exactly 50% duty cycle?
With positive values for both timing resistors, the high time is longer than the low time. To reach 50% or below, use a circuit with a different charge and discharge path or divide the clock externally.
Why is the monostable formula about 1.1RC?
The capacitor charges from near zero to approximately two thirds of the supply through R. The ideal exponential reaches that threshold at ln(3) × R × C, which is about 1.0986RC.
Why does my measured frequency differ from the calculator?
Check the resistance and capacitance at actual operating conditions, then consider leakage, threshold variation, and circuit loading. A timing calculation starts with ideal parts.
Technical references · Texas Instruments NE555 datasheet