555 Timer Calculator

Astable Frequency · Duty Cycle · Monostable Pulse Width

Timing and component values

Calculate the timing of a circuit or find resistor values for your target waveform.

Set up your timing network

Resistor RA
Resistor RB
Timing capacitor C

RA and RB set the high time. RB sets the low time.

Examples
Component tolerance

Enter symmetric limits from the part specs. The range covers R and C only.

Oscillator frequency

1.387 kHz

54.8% of each cycle is high.

Period
720.9 µs
High time
395.1 µs
Low time
325.8 µs
Output high duty
54.8%

How to use this calculator

Design a repeating clock or a single timed pulse with a 555 timer. Choose astable mode for a repeating square wave or monostable mode for a one-shot. Start from the parts you have, or work backward from the timing you want.

555 timer astable and monostable timing circuits The astable circuit charges its timing capacitor through two resistors and discharges through the second resistor. Its output repeats. The monostable circuit charges its timing capacitor through one resistor after a low trigger and makes one output pulse. Pin numbers are shown for the standard eight pin layout. 555 timer timing circuits One capacitor sets the time scale in both modes. Astable Repeating output 8 VCC 4 RESET 7 DISCH 6 THRES 2 TRIG 3 OUT 1 GND VCC RA RB C 555 OUT VC High Low C charges through RA + RB and discharges through RB. Monostable One pulse per trigger 8 VCC 4 RESET 7 DISCH 6 THRES 2 TRIG 3 OUT 1 GND VCC Trigger Output R C 555 OUT VC Triggered high pulse C charges through R. The output goes low at ⅔ VCC. Simplified timing circuits. Pin 5 and supply bypass components are omitted. Waveforms are idealized.
In astable mode the timing capacitor repeatedly charges and discharges. In monostable mode a trigger starts one timed output pulse.

Astable mode for a repeating square wave

In the standard two resistor circuit, the capacitor charges through RA and RB and discharges through RB. The 555’s internal comparators switch at approximately one third and two thirds of the supply voltage.

thigh = ln(2) × (RA + RB) × C
tlow = ln(2) × RB × C

Add the two times to get the period. Frequency is one divided by the period, and duty cycle is the fraction spent high. With RA = 10 kΩ, RB = 47 kΩ, and C = 10 nF, the audio oscillator example gives about 1.39 kHz with a 54.8% high duty cycle.

Monostable mode for a single timed pulse

A short trigger drives the output high and lets the capacitor charge through one resistor. When the capacitor reaches the upper threshold, the output returns low. The ideal pulse lasts ln(3) × R × C, often rounded to 1.1RC.

A 91 kΩ resistor and a 1 µF capacitor give about 100 milliseconds. To choose components for a target pulse, start with a capacitor that suits the time range and solve for its resistor. Keep the trigger short enough for the one-shot circuit described in the device datasheet.

From calculated timing to the bench

Start with the timing spread from component tolerance. Allow for capacitor leakage and variation, the timer’s threshold accuracy, temperature, and supply conditions as well. Check the datasheet for the exact 555 variant. A bipolar NE555 and a CMOS replacement can have different operating limits.

Frequently asked questions

What is the difference between astable and monostable modes?

Astable mode repeats high and low intervals without a separate trigger for each cycle. Monostable mode produces one timed output pulse in response to a trigger.

Can the standard astable 555 circuit reach exactly 50% duty cycle?

With positive values for both timing resistors, the high time is longer than the low time. To reach 50% or below, use a circuit with a different charge and discharge path or divide the clock externally.

Why is the monostable formula about 1.1RC?

The capacitor charges from near zero to approximately two thirds of the supply through R. The ideal exponential reaches that threshold at ln(3) × R × C, which is about 1.0986RC.

Why does my measured frequency differ from the calculator?

Check the resistance and capacitance at actual operating conditions, then consider leakage, threshold variation, and circuit loading. A timing calculation starts with ideal parts.

Technical references · Texas Instruments NE555 datasheet

Consult with an Expert

Get a formal quote

Get a formal quote